- Inverter power, single phase
- 3–8 kW
- Inverter power, three phase
- 5–15 kW
- AC output
- On-grid, off-grid, generator backup
- On/off-grid switch time
- 10 ms (UPS function)
- All-in-one
- Hybrid inverter, batteries, UPS and EMS in one system
- Parallel inverters
- Up to 4, on-grid and off-grid
- Chemistry
- LFP, Tier 1 cells
- Cell capacity
- 314 Ah
- Cycle life
- 8,000 cycles
- Capacity
- 8–128 kWh, modular stacked
- Energy per module
- 8 kWh total, 7.2 kWh usable
- Max. charge/discharge power
- 15 kW in one system
- Battery voltage range
- 20–60 V
- Redundancy
- 1+1 redundancy design
- Protection
- 5 layers of protection
- Control
- Dual redundant MCU control
- Fire
- Fire suppression module
- Thermal
- Multi-module temperature sampling, thermal shield, heat module
- Surge protection
- Type II SPD on AC and DC sides
- Battery standards
- UN38.3, IEC 62619, IEC 62040, EMC
- Inverter standards
- IEC/EN 62109-1/2, EN 50549-1/10, AS4777.1, IEC 61727, IEC 62116, C10/C11, N4105, IEC 61000, CEI 0-21, IEC 61683
- MPPTs
- 3 independent
- String current
- Up to 20 A
- DC/AC ratio
- Up to 2.0
- Operating temperature, battery
- −20 °C to 55 °C (charging and discharging)
- Operating temperature, inverter
- −30 °C to 60 °C (derating above 45 °C)
- Heating module
- Integrated, for operation below 0 °C
- Ingress protection
- IP66 (battery and inverter)
- Installation
- Indoor and outdoor; floor standing or wall-mounted
- Grid
- Works with 1-phase and 3-phase systems